Receptor PQR Handoff

External protonation and charge handoff documentation

Open an external PDB2PQR-style workflow and keep preparation notes for receptor protonation and charge assignment.

Step-by-step documentationLocal browser fileVersion 0.14.4-alpha

How to cite this tool

Use this citation text and add the date accessed if the file is hosted online or shared through a repository.

Weiss AKH. Receptor PQR Handoff. akhw.at local browser tools, version 0.14.4-alpha, build 2026-06-12-tools5. PHP documentation: docs/receptor-pqr-handoff.php.

What this page is supposed to do

This page is a checkpoint between receptor cleanup and PDBQT conversion. It reminds the user that receptor charges and protonation are not created by the cleanup page and must be generated through a dedicated external workflow or another validated route.

Use this page when

  • You have exported a clean receptor PDB.
  • You need to generate a receptor PQR file with charges and radii.
  • You want to record pH, force-field, and preparation choices before returning to PDBQT conversion.

Do not use it as

  • Do not skip this step when the downstream converter expects a PQR file.
  • Do not assume default pH or force-field settings are appropriate for every system.
  • Do not upload confidential structures to external services unless the project permits it.

At a glance

QuestionAnswer
Primary jobBridge local cleanup to external receptor protonation and charge assignment.
Main riskUsing wrong protonation, force-field, or privacy assumptions.
Best next stepDownload PQR, then load receptor PDB plus PQR into PDBQT Converter.
Reproducibility filePQR file, clean PDB, pH, force-field, and note record.

Typical inputs

  • Clean receptor PDB from Receptor PDB Clean or another curated source.
  • Chosen pH and force-field or parameter settings for the external workflow.
  • Optional notes stored in the browser.

Typical outputs

  • Externally generated PQR file.
  • User notes documenting selected settings.
  • A preparation record that can be kept with receptor PDBQT conversion files.

Where it fits in the docking workflow

  1. 0
    Ligand Draw

    Create or import a ligand starting structure.

  2. 1
    Ligand Prep

    Inspect ligand chemistry, metadata, and torsion restrictions.

  3. 2
    Receptor PDB Clean

    Clean a receptor PDB and decide what to keep.

  4. 3
    Receptor PQR Handoff

    Assign receptor protonation and charges with an external PQR workflow.

  5. 4
    PDBQT Converter

    Convert cleaned receptor and prepared ligand material to docking-ready PDBQT.

  6. 5
    Vina Setup

    Define the docking box and export a Vina-style configuration.

  7. 6
    Vina Run

    Run or emulate docking and inspect poses, scores, and warnings.

Step-by-step use

  1. Start with a clean receptor PDB. Do not use an unreviewed crystallographic file if the cleanup step has not been completed.
  2. Read the before-you-continue checklist. Confirm that chains, waters, cofactors, metals, and reference ligand decisions have already been made.
  3. Decide whether an external web service is acceptable for the project. If the structure is confidential, use a local or approved institutional route instead.
  4. Choose the intended pH and parameter settings before opening the external workflow. Write them down in the notes area so the choice is not lost.
  5. Open PDB2PQR or the external workflow from the page. Upload the cleaned receptor PDB there, not the original uncleaned file unless that is deliberate.
  6. Run the external calculation with the chosen settings. Read the external output messages and warnings. Warnings about missing atoms, unusual residues, or failed assignments matter downstream.
  7. Download the PQR output. Keep its original filename or rename it so it stays paired with the cleaned PDB.
  8. Return to the handoff page and save notes in the browser if needed. Include pH, force field, date, external service or local tool name, and any warnings.
  9. Proceed to PDBQT Converter with both receptor files: the cleaned PDB and the generated PQR.

How to interpret what you see

PDB input
Provides coordinates and residue records for the external preparation step.
PQR output
Contains coordinates plus charge and radius information used by downstream conversion.
pH setting
Influences protonation choices. It must match the scientific question.
Notes
A lightweight reproducibility record. Export or copy them if browser storage is not enough.
Auto-redirect
A convenience feature only. It does not validate your structure or settings.

Quality-control checklist before moving on

Troubleshooting

ProblemWhat to check
The external page does not open.Open the service manually in a new tab or use a local approved PQR workflow.
External service rejects the PDB.Return to Receptor PDB Clean and inspect non-standard residues, malformed records, missing atoms, and chains.
PQR output is empty or incomplete.Review external warnings and rerun with corrected input or settings.
Notes disappear.Browser storage can be cleared. Copy important notes into a project text file.
The page opens but looks unstyled.The documentation expects the package assets folder at ../assets. If you copied only the docs folder, place it back inside the full tools directory.
Special characters display as garbled text.Serve the page as UTF-8 and keep the PHP header at the top of the file. Do not resave the file in a legacy encoding.
A button does nothing.Check whether a file must be loaded first, whether the browser blocked a popup, or whether a required external service is offline.
The output seems scientifically wrong.Stop the workflow. Check the input format, warnings, protonation state, atom typing, grid placement, and whether the tool is only a helper for that step.

Practical notes

Copyright and disclaimer

Copyright © 2026 Alexander Weiss, akhw.at. All rights reserved.

Research workflow helper only. External tools and services have their own licenses, terms, privacy implications, citation requirements, and scientific limitations. Validate protonation and charge assignment before use in decisions or publications.