Receptor PQR Handoff
Open an external PDB2PQR-style workflow and keep preparation notes for receptor protonation and charge assignment.
How to cite this tool
Use this citation text and add the date accessed if the file is hosted online or shared through a repository.
What this page is supposed to do
This page is a checkpoint between receptor cleanup and PDBQT conversion. It reminds the user that receptor charges and protonation are not created by the cleanup page and must be generated through a dedicated external workflow or another validated route.
Use this page when
- You have exported a clean receptor PDB.
- You need to generate a receptor PQR file with charges and radii.
- You want to record pH, force-field, and preparation choices before returning to PDBQT conversion.
Do not use it as
- Do not skip this step when the downstream converter expects a PQR file.
- Do not assume default pH or force-field settings are appropriate for every system.
- Do not upload confidential structures to external services unless the project permits it.
At a glance
| Question | Answer |
|---|---|
| Primary job | Bridge local cleanup to external receptor protonation and charge assignment. |
| Main risk | Using wrong protonation, force-field, or privacy assumptions. |
| Best next step | Download PQR, then load receptor PDB plus PQR into PDBQT Converter. |
| Reproducibility file | PQR file, clean PDB, pH, force-field, and note record. |
Typical inputs
- Clean receptor PDB from Receptor PDB Clean or another curated source.
- Chosen pH and force-field or parameter settings for the external workflow.
- Optional notes stored in the browser.
Typical outputs
- Externally generated PQR file.
- User notes documenting selected settings.
- A preparation record that can be kept with receptor PDBQT conversion files.
Where it fits in the docking workflow
- 0Ligand Draw
Create or import a ligand starting structure.
- 1Ligand Prep
Inspect ligand chemistry, metadata, and torsion restrictions.
- 2Receptor PDB Clean
Clean a receptor PDB and decide what to keep.
- 3Receptor PQR Handoff
Assign receptor protonation and charges with an external PQR workflow.
- 4PDBQT Converter
Convert cleaned receptor and prepared ligand material to docking-ready PDBQT.
- 5Vina Setup
Define the docking box and export a Vina-style configuration.
- 6Vina Run
Run or emulate docking and inspect poses, scores, and warnings.
Step-by-step use
- Start with a clean receptor PDB. Do not use an unreviewed crystallographic file if the cleanup step has not been completed.
- Read the before-you-continue checklist. Confirm that chains, waters, cofactors, metals, and reference ligand decisions have already been made.
- Decide whether an external web service is acceptable for the project. If the structure is confidential, use a local or approved institutional route instead.
- Choose the intended pH and parameter settings before opening the external workflow. Write them down in the notes area so the choice is not lost.
- Open PDB2PQR or the external workflow from the page. Upload the cleaned receptor PDB there, not the original uncleaned file unless that is deliberate.
- Run the external calculation with the chosen settings. Read the external output messages and warnings. Warnings about missing atoms, unusual residues, or failed assignments matter downstream.
- Download the PQR output. Keep its original filename or rename it so it stays paired with the cleaned PDB.
- Return to the handoff page and save notes in the browser if needed. Include pH, force field, date, external service or local tool name, and any warnings.
- Proceed to PDBQT Converter with both receptor files: the cleaned PDB and the generated PQR.
How to interpret what you see
- PDB input
- Provides coordinates and residue records for the external preparation step.
- PQR output
- Contains coordinates plus charge and radius information used by downstream conversion.
- pH setting
- Influences protonation choices. It must match the scientific question.
- Notes
- A lightweight reproducibility record. Export or copy them if browser storage is not enough.
- Auto-redirect
- A convenience feature only. It does not validate your structure or settings.
Quality-control checklist before moving on
- Clean PDB, not raw PDB, was submitted intentionally.
- pH and force-field settings are recorded.
- External warnings were reviewed.
- PQR output was downloaded and paired with the matching PDB.
- Project privacy rules allow the external workflow, or a local alternative was used.
Troubleshooting
| Problem | What to check |
|---|---|
| The external page does not open. | Open the service manually in a new tab or use a local approved PQR workflow. |
| External service rejects the PDB. | Return to Receptor PDB Clean and inspect non-standard residues, malformed records, missing atoms, and chains. |
| PQR output is empty or incomplete. | Review external warnings and rerun with corrected input or settings. |
| Notes disappear. | Browser storage can be cleared. Copy important notes into a project text file. |
| The page opens but looks unstyled. | The documentation expects the package assets folder at ../assets. If you copied only the docs folder, place it back inside the full tools directory. |
| Special characters display as garbled text. | Serve the page as UTF-8 and keep the PHP header at the top of the file. Do not resave the file in a legacy encoding. |
| A button does nothing. | Check whether a file must be loaded first, whether the browser blocked a popup, or whether a required external service is offline. |
| The output seems scientifically wrong. | Stop the workflow. Check the input format, warnings, protonation state, atom typing, grid placement, and whether the tool is only a helper for that step. |
Practical notes
- Keep the original input files unchanged. Save all exports into a project folder with a clear date and version note.
- Do not use a generated result only because the page produced it. Inspect warnings, inputs, assumptions, and output format before moving to the next step.
- For publication, reporting, or operational decisions, validate the result with established scientific software and cite the final software versions and settings.
- Treat browser storage as temporary. Export session JSON or report files whenever you need a reproducible record.
Copyright and disclaimer
Copyright © 2026 Alexander Weiss, akhw.at. All rights reserved.
Research workflow helper only. External tools and services have their own licenses, terms, privacy implications, citation requirements, and scientific limitations. Validate protonation and charge assignment before use in decisions or publications.