How to cite: Weiss AKH. O2k DLD Graph Viewer. akhw.at local browser tools, version 0.14.12-alpha, build 2026-06-18-o2no-norm-gray. PHP tool: dld-viewer.php.
Documentation

Oroboros DatLab 7 .DLD graph viewer

Experimental local viewer for reverse-engineered DatLab 7 time-series records. The original file is never modified or uploaded. Version 0.14.12-alpha, build 2026-06-18-o2no-norm-gray.
Copyright © 2026 Alexander Weiss, akhw.at. All rights reserved. Unofficial reverse-engineered tool, not affiliated with Oroboros Instruments. Validate quantitative results against DatLab exports before publication.

Drop a .DLD file here or choose one from disk
No file loaded.
DLD information
Plot setup
O2 flux units
No DLD flux-unit metadata loaded yet.
For O2 flux only: raw flux × unit factor × 60 ÷ chamber volume. Chamber normalization is then applied, for example divide by million cells, and baseline subtraction comes last. Y-axis controls never scale the data.
O2 level units
No O2 level conversion detected yet.
For O2 level channels only: raw O2 signal × unit factor. Chamber normalization and baseline/blank subtraction are not applied to O2 levels.
Y axes
Leave min, max, tick, or label empty to use automatic axes. Manual min, max, and tick are absolute plotted values. They only change the visible axis window, never the data. Baseline correction is pure subtraction: corrected = chamber-normalized value minus the baseline Mark mean.
Chamber A upper panel
Chamber B lower panel
Tick is the major tick spacing in absolute plotted units. Manual min/max do not change mark calculations, only the displayed axis.
Cut left and right
Cutting hides useless beginning/end regions for plotting, analysis and plotted export. It is non-destructive.
Times use the selected X-axis unit.
Excluded sections
Use this for artefacts or internal parts to exclude from plotting/exported plotted values and mark summaries. The timeline is kept. By default, the hidden data are still shown as a faint gray ghost trace over the red region.
Events
Events are point annotations such as injections or comments. Double-click the plot to add one.
Marks and baseline correction
Marks are analysis regions. Their means and SDs are listed below the plot. One mark can be used as a baseline/blank for Y-offset correction. Baseline correction subtracts the Mark mean only.
Chamber normalization
Use separate factors for chamber A and chamber B, for example cell number, cell density, protein, tissue mass, or a chamber-specific scaling factor.
No DLD normalization metadata loaded yet.
Correction order for non-O2-level channels: chamber normalization first, then baseline subtraction only. O2 level channels ignore chamber normalization and baseline subtraction. Detected DLD factors are applied automatically to plot scaling, Mark summaries, derived bars, and auto Y axes for applicable channels. Unknown or zero chamber factors are treated as 1.
Data families
Master switches: choose which data families are considered for plots, Mark summaries, and derived diagrams. O2 flux is enabled by default; pX, NO/NC and system channels stay off unless needed.
Turning a family off hides it from the channel list and prevents it from contributing to Mark summaries and auto-generated diagrams. Existing project selections are preserved but ignored until the family is re-enabled.
Derived bar diagrams
Primary diagrams: O2 flux comparisons. These are generated from Mark summaries after O2 flux unit conversion, chamber normalization, and optional baseline subtraction.
A/B chamber diagrams
These diagrams compare Chamber A with Chamber B per Mark label. O2 flux per-Mark diagrams are recommended and can be selected in one click.
Mark-comparison diagrams
Auto-generated from Mark labels. Each selected option creates a square diagram with two bars: Chamber A and Chamber B.
O2 flux Mark comparisons are enabled automatically when possible. Other metrics remain available but are lower priority.
Channels
Save, load, export
Project JSON stores the DLD file itself plus selected channels, derived diagrams, cuts, scoped excluded sections, scoped events, scoped marks, per-chamber baselines, normalization, absolute Y-axis limits, style, and zoom. Refresh DLD annotations reparses the embedded/loaded file while keeping edits. Reload data from DLD reparses a chosen replacement file and keeps the current sheet settings where possible. Save PNG exports only the main trace plot, without derived bar diagrams and without the hover tooltip overlay.
wheel zoom X drag pan double-click add event Blue regions are scoped Marks. Red regions are scoped excluded sections; faint gray traces inside them show omitted data. Chamber A is plotted above chamber B. Derived diagrams are generated as square bar cards at the bottom.

Mark summary

No marks yet. Add mark regions to compute averages and SD.
MarkMark scopeChannelChambernMeanSDStartEnd
No data.

Derived bar diagrams

Select derived ratios or mark comparisons to generate square bar diagrams.